Choosing Cable by Loss Budget: The 3-Step Reverse Method

RF Feeder System Technical Guide · PTL Cable (Hangzhou Putianle Cable Co., Ltd.)

Most spec sheets list attenuation "per 100 m at 900 MHz / 2 GHz" — but in the field you start from the opposite end: "my link can tolerate at most X dB loss over Y meters at this frequency, what cable do I need?" Here is the reverse-engineering method our application engineers use.

Step 1 — Define the loss budget

Start from system requirements, not from a catalogue:

Required attenuation per 100 m = (Max allowable loss ÷ L) × 100. This single number drives the whole selection.

Step 2 — Match to a cable family

Lower required dB/100m ⇒ larger, lower-loss cable. Typical 50Ω feeder reference values (≈ values at 900 MHz):

CableTypeAtten. ≈ dB/100m @900MHzUse when
PTL240 / LMR240Braided~12–14Short indoor/DAS jumps
PTL400 / LMR400Braided~6.5–7.5Medium runs, flexible routing
1/2″ corrugatedCu/Al tube~4.5–5.5Building-to-antenna feeders
7/8″ corrugatedCu/Al tube~2.8–3.2Macro base-station trunks
1-5/8″ corrugatedCu/Al tube~1.6–1.9Long high-power runs

Pick the smallest cable whose attenuation ≤ your Step-1 number, then verify at your actual frequency (use the full datasheet curves, not just the 900 MHz point).

Step 3 — Validate with margin and connectors

Worked example

Requirement: 60 m feeder at 2.1 GHz, max 3.0 dB loss; flexible routing preferred.

Step 1: 3.0 ÷ 60 × 100 = 5.0 dB/100m at 2.1 GHz.

Step 2: At 2.1 GHz, 1/2″ corrugated ≈ 8–9 dB/100m (too high); PTL400 braided ≈ 11 dB/100m (too high); 7/8″ corrugated ≈ 5 dB/100m — meets it. If routing flexibility is critical and runs shorter, PTL600 braided may also qualify.

Step 3: Choose 7/8″ corrugated copper-tube feeder with 7/16 DIN connectors, +1 dB margin → validated.

Need a quick sizing for your project?

Send us frequency, length and allowable loss and we'll return a recommended model with the measured attenuation curve.