For RF engineers specifying coaxial feeder cables, VSWR (Voltage Standing Wave Ratio) and return loss are the two numbers that tell you how much of your transmitted power actually reaches the antenna — and how much is bouncing back as heat and interference. This guide gives you a ready-to-use conversion table and a field checklist.
In an ideal 50Ω RF system, the cable, connectors and antenna all present a perfect 50Ω load. In reality, any mismatch creates a reflected wave. Two ways to express the same mismatch:
1.0:1 = perfect; 1.5:1 is a common acceptance limit; >2.0:1 signals a real problem.20 dB ≈ near-perfect; 14 dB ≈ VSWR 1.5.| VSWR | Return Loss (dB) | Reflected Power | Assessment |
|---|---|---|---|
| 1.00:1 | ∞ | 0% | Ideal |
| 1.10:1 | 26.4 | 0.2% | Excellent |
| 1.20:1 | 20.8 | 0.8% | Very good |
| 1.30:1 | 17.7 | 1.7% | Good |
| 1.50:1 | 14.0 | 4.0% | Acceptable limit |
| 1.80:1 | 11.0 | 7.7% | Marginal |
| 2.00:1 | 9.5 | 11.1% | Poor — investigate |
| 3.00:1 | 6.0 | 25.0% | Bad |
Quick rule: every 3 dB of return loss ≈ doubling of reflected power. A field limit of VSWR ≤ 1.5 (return loss ≥ 14 dB) is the standard acceptance criterion for most base-station feeder installations.
Reflected power is not just "lost signal" — it heats the cable and connectors, degrades the transmitter, and raises the noise floor. In a corrugated copper-tube feeder running 1/2″ to 1-5/8″ at a macro base station, keeping VSWR under 1.3 across 700 MHz–2.6 GHz protects both link budget and hardware life.
Consistent 50Ω impedance depends on precise dielectric and concentricity. Our 50Ω corrugated copper and aluminium-tube coaxial and PTL braided series (LMR-equivalent) are 100% tested on vector network analyzers before shipment, with VSWR certificates available per lot.