125C Irradiated XLPO Sheath (LZ-E12560)
125C irradiated XLPO sheath compound for building wires requiring bundle A/B/C flame retardancy. Typical tensile 12MPa, elongation 180%, heat aging within 8%, dielectric strength 25kV/mm, oxygen index 33, GB/T 10491-2022 compliant.
125℃
Irradiated Cross-linked Cable Compound
Custom lengths, connectors and pre-assembled jumpers are available. Send us your specification for a quotation.
Technical data
Specifications
Specification
| Model | 125℃ |
|---|---|
| Category | Irradiated Cross-linked Cable Compound |
| Options | Custom length, connectors and pre-assembled assemblies |
Product description
125C irradiated XLPO sheath compound for building wires requiring bundle A/B/C flame retardancy. Typical tensile 12MPa, elongation 180%, heat aging within 8%, dielectric strength 25kV/mm, oxygen index 33, GB/T 10491-2022 compliant.